9-32
Cisco SCE8000 GBE Installation and Configuration Guide
Chapter 9 Removal and Replacement Procedures
Installing a SPA in a SIP
Installing a SPA in a SIP
To install a SPA in a SIP, see Figure 9-17 and do the following:
Step 1 At the SCE8000# prompt, enter reload shutdown and press Enter to power down the Cisco SCE 8000
platform before installing or removing any module.
Step 2 To insert the SPA in the SIP, locate the guide rails inside the SIP that hold the SPA in place. They are at
the top left and top right of the SPA slot and are recessed about an inch, as shown in Figure 9-17.
Step 3 Carefully slide the SPA into the SIP until the SPA is firmly seated in the SPA interface connector. When
fully seated, the SPA might be slightly behind the SIP faceplate.
Step 4 After the SPA is properly seated, fasten the SPA in place with the captive installation screws.
Removing a SPA from a SIP
To remove a SPA from a SIP, see Figure 9-17 and do the following:
Step 1 At the SCE8000# prompt, enter reload shutdown and press Enter to power down the Cisco SCE 8000
platform before installing or removing any module.
Step 2 If attached, remove any cables from the SPA.
Step 3 To remove the SPA from the SIP, unfasten the captive installation screws on the SPA.
Step 4 Grasp the handles of the SPA and pull the SPA from the SIP.