C-2
Cisco SCE8000 GBE Installation and Configuration Guide
Appendix C Cisco Service Control Engine System Log Messages
Fatal Messages, Severity Level 2
• Warning Messages, Severity Level 4
• Notice Messages, Severity Level 5
Fatal Messages, Severity Level 2
Fatal Message %LOCAL7-2-SE_USER_FATAL "SE <%s> Module: A Fatal Error occurred.
Please report to Cisco's customer support"
Explanation
This message is generated to inform that a fatal error has occurred.
Recommended Action Report this to Cisco Customer Support.
Fatal Message %LOCAL7-2-LOGGER_USER_FATAL_MSG "<%s>"
Explanation
This message is generated while you add your own fatal messages to the user log file
using the logger add-user-message command in the CLI.
Recommended Action None.
Fatal Message %LOCAL7-2-DP_CLS_SEQ_ERR "HW internal error
Explanation
This is an internal hardware error. This fatal hardware interrupt is generated when there
is a mismatch in the sequence of messages to the classifier.
Recommended Action None.
Fatal Message %LOCAL7-2-CLS_FF_SEQ_ERR "HW internal error
Explanation
This is an internal hardware error. This fatal hardware interrupt is generated when there
is a mismatch in the sequence of messages to the flow filter.
Recommended Action None.
Fatal Message %LOCAL7-2-DP_IN_SEQ_ERR "HW internal error
Explanation
This is an internal hardware error. This fatal hardware interrupt is generated when there
is a mismatch in the sequence of the dispatcher input messages.
Recommended Action None.
Fatal Message %LOCAL7-2-DP_OUT_SEQ_ERR "HW internal error
Explanation
This is an internal hardware error. This fatal hardware interrupt is generated when there
is a mismatch in the sequence of the dispatcher output messages.
Recommended Action None.