4 Configuration DGS-1210 series Metro Ethernet Managed Switch User Manual
7
7
7
7
Figure 4.106 - Configuration > DDM > DDM Temperature Threshold Settings
Port: Specifies the port to be configured.
Type: Specifies the type for the operating parameter, the options are High Alarm, Low Alarm, High Warning
and Low Warning.
High Alarm: Specifies the high threshold for the alarm. When the operating temperature rises above
the configured value, the action associated with the alarm is taken.
Low Alarm: Specifies the low threshold for the alarm. When the operating temperature falls below
the configured value, the action associated with the alarm is taken.
High Warning: Specifies the high threshold for the warning. When the operating temperature rises
above the configured value, the action associated with the warning is taken.
Low Warning: Specifies the low threshold for the warning. When the operating temperature falls
below the configured value, the action associated with the warning is taken.
Vaule (-128 – 127.996): Specifies the value for the specified type of port.
Click Apply to make the configurations take effect.
Configuration > DDM > DDM Voltage Settings Threshold Settings
The DDM Voltage Settings Threshold Settings page is used to configure the DDM voltage threshold for
specific ports on the Switch.
Figure 4.107 - Configuration > DDM > DDM Voltage Settings Threshold Settings
Port: Specifies the port to be configured.
Type: Specifies the type for the operating parameter, the options are High Alarm, Low Alarm, High Warning
and Low Warning.
High Alarm: Specifies the high threshold for the alarm. When the operating Voltage rises above the
configured value, the action associated with the alarm is taken.
Low Alarm: Specifies the low threshold for the alarm. When the operating Voltage falls below the
configured value, the action associated with the alarm is taken.
High Warning: Specifies the high threshold for the warning. When the operating Voltage rises
above the configured value, the action associated with the warning is taken.

Table of Contents

Other manuals for D-Link DGS-1210-28/ME

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the D-Link DGS-1210-28/ME and is the answer not in the manual?

D-Link DGS-1210-28/ME Specifications

General IconGeneral
BrandD-Link
ModelDGS-1210-28/ME
CategorySwitch
LanguageEnglish

Related product manuals