Enter/Exit Programming Mode
Product Reference Guide
125
I 2 of 5 Check Character Transmission
Enable this option to transmit the check character along with I 2 of 5 bar
code data.
$CI2CT00(CR)
I 2 of 5 Check Character Transmission = Don’t Send
$CI2CT01(CR)
I 2 of 5 Check Character Transmission = Send
DEFAULT
I 2 of 5 Length Control
This feature specifies either variable length decoding or fixed length decod-
ing for the I 2 of 5 symbology.
Variable Length:
For variable length decoding, a minimum and maximum
length may be set.
Fixed Length:
For fixed length decoding, two different lengths may be set.
DEFAULT
$CI2LC00(CR)
I 2 of 5 Length Control = Variable Length
$CI2LC01(CR)
I 2 of 5 Length Control = Fixed Length

Table of Contents

Other manuals for Datalogic PowerScan PD9530

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic PowerScan PD9530 and is the answer not in the manual?

Datalogic PowerScan PD9530 Specifications

General IconGeneral
TypeHandheld bar code reader
Sensor typeLaser
Tilt reading angle0 - 360 °
Pitch reading angle-40 - 40 °
Linear (1D) barcodes supported-
Standard interfacesRS-232, USB, Keyboard wedge
Connectivity technologyWired
Product colorBlack, Yellow
International Protection (IP) codeIP65
Input voltage5 V
Power consumption350 mA
Power source typeDC
Storage temperature (T-T)-40 - 70 °C
Operating temperature (T-T)-20 - 50 °C
Operating relative humidity (H-H)0 - 95 %
Cables includedNo
Weight and Dimensions IconWeight and Dimensions
Depth110 mm
Width74 mm
Height212 mm
Weight330 g