Scanning Features
Product Reference Guide
297
Scanning Active Time
This setting specifies the amount of time that the reader stays in scan ON
state once the state is entered. The range for this setting is from 1 to 255
seconds in 1-second increments.
Follow these instructions to set this feature:
1. Determine the desired setting.
2. Pad the result with leading zeroes to yield three digits. For example: 0
= 000
,
5 = 005, 20 = 020, etc.
3. Go to page 74 and scan the ENTER/EXIT PROGRAMMING MODE bar code
to enter Programming Mode.
4. Scan the bar code: SELECT SCANNING ACTIVE
TIME SETTING.
5. Scan the appropriate three digits from the keypad in Appendix D, Key-
pad, that represent the duration which was determined in the steps
above. You will hear a two-beep indica
tion after the last character.
If you make a mistake before the last character, scan the CANCEL bar
code to abort and not save the entry string. You can then start again
at the beginning.
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Program-
ming Mode.
This completes the procedure. See Table 42 for some examples of how to
set this feature.
Table 42. Scanning Active Time Setting Examples
STEP ACTION EXAMPLES
1 Desired Setting
1 Second 90 Sec. (1.5 min.) 180 Sec. (3 min.)
255 Seconds (4.25
min.)
2 Pad leading zero(es)
001 090 180 255
3 Scan ENTER/EXIT PROGRAMMING MODE
4 Scan SELECT SCANNING ACTIVE TIME SETTING
5
Scan Three Characters
From
Appendix D,
Keypad
‘0’, ‘0’ and ‘1’ ‘0’, ‘9’ and ‘0’ ‘1’, ‘8’ and ‘0’ ‘2’, ‘5’ and ‘5’
6 Scan ENTER/EXIT PROGRAMMING MODE

Table of Contents

Other manuals for Datalogic PowerScan PD9530

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic PowerScan PD9530 and is the answer not in the manual?

Datalogic PowerScan PD9530 Specifications

General IconGeneral
TypeHandheld bar code reader
Sensor typeLaser
Tilt reading angle0 - 360 °
Pitch reading angle-40 - 40 °
Linear (1D) barcodes supported-
Standard interfacesRS-232, USB, Keyboard wedge
Connectivity technologyWired
Product colorBlack, Yellow
International Protection (IP) codeIP65
Input voltage5 V
Power consumption350 mA
Power source typeDC
Storage temperature (T-T)-40 - 70 °C
Operating temperature (T-T)-20 - 50 °C
Operating relative humidity (H-H)0 - 95 %
Cables includedNo
Weight and Dimensions IconWeight and Dimensions
Depth110 mm
Width74 mm
Height212 mm
Weight330 g