Enter/Exit Programming Mode
48
PowerScan™ PD9530/PBT9500/PM9500
USB-OEM Device Usage
The USB-OEM protocol allows for the reader to be identified as one of two
different types of bar code scanners. Depending on what other scanners you
may already have connected to a USB-OEM POS, you may need to change
this setting to enable all devices to communicate.
Options are:
• Table Top Scanner
• Handheld Scanner
USB-OEM Device Usage = Table Top Scanner
USB-OEM Device Usage = Handheld Scanner
DEFAULT
It may be necessary to switch device usage when connecting two readers/scanners of
the same type to a POS system.
Interface Options
Obey Scanner Configuration Host Commands
Ignore Scanner Configuration Host Commands
DEFAULT
This feature provides for an interface-specific control mechanism.