Wireless Features
Product Reference Guide
305
STAR Radio Protocol Timeout
This parameter sets the valid wait time before transmission between the
handheld reader and Base Station is considered failed.
When setting this parameter, take into
considerat
ion the radio traffic (num-
ber of readers in the same area). The selectable range for this feature is from
02 to
25 seconds.
Follow these instructions to set this feature:
1. Determine the desired setting.
2. Pad the number with leading zeroes to yield two digits. For example: 2
= 02, 5 = 05, 25
= 25, etc
3. Go to page 236 and scanScan the ENTER/EXIT PROGRAMMING MODE
barcode to enter Programming Mode.
4. Scan the barcode: SELECT RADIO PROTOCOL TIMEOUT.
5. Scan the appropriate two digits from the keypad in Appendix D, Key-
pad, that represent the duration which was determined in the steps
above. You will hear a two-beep indic
a
tion after the last character.
If you make a mistake before the last character, scan the CANCEL bar-
code to abort and not save the entry string. You can then start again
at the beginning.
6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Program-
ming Mode.
This completes the procedure. See Table 50 for some examples of how to
set this feature.
Table 50. STAR Radio Protocol Timeout Examples
STEP ACTION EXAMPLES
1 Desired Setting
2 Seconds 5 Seconds 10 Seconds 25 Seconds
2 Pad with leading zero(es)
02 05 10 25
3 Scan ENTER/EXIT PROGRAMMING MODE
4 Scan SELECTSTAR RADIO PROTOCOL TIMEOUT SETTING
5
Scan Two Characters From
Appendix D, Keypad
‘0’ and ‘2’ ‘0’ and ‘5’ ‘1’ and ‘0’ ‘2’ AND ‘5’
6 Scan ENTER/EXIT PROGRAMMING MODE

Table of Contents

Other manuals for Datalogic PowerScan PD9530

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic PowerScan PD9530 and is the answer not in the manual?

Datalogic PowerScan PD9530 Specifications

General IconGeneral
TypeHandheld bar code reader
Sensor typeLaser
Tilt reading angle0 - 360 °
Pitch reading angle-40 - 40 °
Linear (1D) barcodes supported-
Standard interfacesRS-232, USB, Keyboard wedge
Connectivity technologyWired
Product colorBlack, Yellow
International Protection (IP) codeIP65
Input voltage5 V
Power consumption350 mA
Power source typeDC
Storage temperature (T-T)-40 - 70 °C
Operating temperature (T-T)-20 - 50 °C
Operating relative humidity (H-H)0 - 95 %
Cables includedNo
Weight and Dimensions IconWeight and Dimensions
Depth110 mm
Width74 mm
Height212 mm
Weight330 g