2.9 Load Cell Module Specifications
2.9.1 General Specifications
AS02LC-A
Item
Description
Rated supply voltage/Power
consumption
24 VDC (-15 to +20%) / 5W
Minimum/maximum voltage
18~31.2VDC
Maximum current consumption
150 mA
Input signal range
±40mVDC
Sensibility
+5 VDC +/-10%
ADC resolution
24 bits
Highest precision
0.04%
Applicable sensor type
Four-wire or six-wire load cell
Expanding a temperature
coefficient
± 50 ppm/K v. E
Reducing a temperature
coefficient to zero
± 0.4 μV/K
Linearity error
≤ 0.02%
Response time
2.5, 10, 16, 20, 50, 60, 100, 200, and 400ms
Eigenvalue applicable to a load
cell
0–1, 02, 04, 06, 020, 040 and 0–80 mV/V
Maximum distance for
connecting a load cell
100 meters
Maximum output current
5 VDC * 160 mA
Allowable load
404,010 Ω
Common-mode rejection ratio
(CMRR @50/60 Hz)
≥100 dB
Extreme pulse value range
0–8
Averaging weights
1–100 (FW V1.04: 1 to 400)
Isolation
Between a digital circuit and the ground: 500 VAC
Between an analog circuit and the ground: 500 VAC
Between an analog circuit and a digital circuit: 500 VAC
Weight
147 g
Send Quote Requests to info@automatedpt.com
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
Send Quote Requests to info@automatedpt.com
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta AS132P-A and is the answer not in the manual?

Delta AS132P-A Specifications

General IconGeneral
BrandDelta
ModelAS132P-A
CategoryNetwork Hardware
LanguageEnglish

Related product manuals