4.12 Load Cell Modules
4.12.1 Wiring AS02LC-A
Converter
4-wire
6-wire
Co nne ct the te rm in al
to th e groun d te rm ina l
System gr oun d
T he 3rd gro und in g
(g roun d resis ta nce of
le ss tha n 100 Ω)
Multiple load cells connected to one load cell module:
Load Cell
CH1
CH2
AS02LC
Load Cell
Load Cell
Load Cell
Load Cell
Load Cell
Load Cell
Load Cell
*1. Connect the of the power module and the of the load cell module to the system ground terminal.
Use the system ground as the third grounding or connect it to the control box.
*2. When connecting multiple load cells, the total resistance of the load cells should be greater than 40 Ω.