Electrical specifications for the outputs on a digital input/output module
Model
08
16AP11
08
16AP11
16AP11
*2
Leakage current
0uA <10uA
<250uA (@V1.00A0)
Max. inrush current
NA Overcurrent protection
7.5A
(Tested condition: Ta =
25
0
C, V
DS
= 30VDC and
Maximum
load
Resistance
2A/output, 8A/COM
0.5A/output, 4A/COM 0.5A/output, 4A/COM
Life cycle curve*
2
12 W (24 VDC) 12 W (24 VDC)
Bulb
20 W (24 VDC)
2 W (24 VDC) 2 W (24 VDC)
1 mA / 5V
Maximum
output
frequency
*1
Resistance
1 Hz 100 Hz 100 Hz
Inductance
0.5 Hz 0.5 Hz 0.5 Hz
1 Hz 10 Hz 10 Hz
Maximum
Response
OFF→ON
< 10 ms < 0.5 ms < 0.5 ms
ON→OFF
< 10 ms < 0.5 ms < 0.5 ms
Output isolation
1500 VAC 500 VAC
Weight
120 g 158 g 138 g 100 g 122 g 120 g 100 g 123 g 120 g
Model
32AN02T-A 64AN02T-A
5–30 VDC
<10uA
Maximum
load
Maximum output
*1
100 Hz (resistance)
Maximum
Response
< 0.5 ms
ON→OFF
500 VAC