4.4 Evaluation of conformity
This device has been subjected to conformity
acceptance testing in accordance with the cur-
rent relevant European Union guidelines. This
equipment conforms to all relevant requirements.
5 Operation
5.1 Handpieces
During treatment using the Paro or Scaler hand-
pieces, they can be operated using just water or
using water and Vector Fluid Polish as required.
Vector Fluid Polish can be switched on or off
using the operating panel.
Paro handpiece
On the Paro handpiece, the Vector basic unit
produces a largely linear vibration of the instru-
ment (perpendicular to the longitudinal axis of the
handpiece) with an adjustable amplitude of
approx. 15–40 mm and a frequency of approx.
23 kHz.
During treatment using the Paro handpiece fluid
is applied as a pulsating jet. Once the flexible foot
switch is released a small amount of fluid will still
drip out. The amount of water that comes out is
pre-defined automatically and cannot be
changed.
Scaler handpiece
On the Scaler LED handpiece, the Vector basic
unit generates a spatial vibration of the instru-
ment tip (transverse to the instrument axis) with
an amplitude of approx. 20–120 mm.
During treatment using the Scaler handpiece,
fluid is applied as a constant stream. The amount
of water that comes out can be adjusted via the
operating panel.
6 LEDs are integrated into the front section of the
handpiece. As soon as the flexible foot switch is
switched on and "Power" is selected on the
operating panel, the LEDs light up.
The LEDs go out approx. 4 seconds after the
flexible foot switch is released.
Handpiece detection
The last used settings in the operating panel are
saved by the relevant handpiece.
After the device is switched off and back on
again the handpiece detection is maintained.
Unplugging the mains plug of the device will
cause the last used settings to be lost.
5.2 Fluid container
The fluid level is monitored via a sensor. When
the level drops to a minimum level, the LEDs in
the area of the fluid container flash and a warning
signal sounds (3x).
Product description
9000-615-28L02 1903V004 15
EN

Table of Contents

Other manuals for Durr Dental Vector Paro

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Durr Dental Vector Paro and is the answer not in the manual?

Durr Dental Vector Paro Specifications

General IconGeneral
BrandDurr Dental
ModelVector Paro
CategoryDental equipment
LanguageEnglish

Related product manuals