Installation and repairs
Installation, readjustments, alterations,
upgrades and repairs must be carried out by
Dürr Dental or by qualified personnel specifi-
cally approved and authorized by Dürr Dental.
2.6 Electrical safety
Comply with all the relevant electrical safety
regulations when working on the unit.
Never touch the patient and unshielded plug
connections on the device at the same time.
Replace any damaged cables or plugs immedi-
ately.
Observe the EMC rules concerning medical
devices
The unit is intended for use in professional
healthcare facilities (in accordance with IEC
60601-1-2). If the appliance is operated in
another environment, potential effects on elec-
tromagnetic compatibility must be taken into
account.
Do not operate the unit in the vicinity of HF sur-
gical instruments or MRT equipment.
Maintain a minimum distance of at least 30 cm
between the unit and other electronic devices.
Keep a minimum distance of 30 cm between
the unit and mobile radio devices.
Note that cable lengths and cable extensions
have effects on electromagnetic compatibility.
The following accessories can have an effect on
the electromagnetic compatibility:
Mains cable
. . . . . . . . . . . . . . . . . . . 9000100846
Flexible foot switch cable . . . . . . 9000-119-130E
NOTICE
Negative effects on the EMC due to
non-authorised accessories
Use only Dürr Dental parts or acces-
sories specifically approved by Dürr
Dental.
Using any other accessories may result
in increased electromagnetic interfer-
ence emissions or the unit having
reduced electromagnetic immunity,
leading to an erroneous operation
mode.
2.7 Only use original parts
Only use Dürr Dental parts or accessories and
special accessories specifically approved by
Dürr Dental.
Only use only original wear parts and replace-
ment parts.
Dürr Dental accepts no liability for dam-
ages or injury resulting from the use of
non-approved accessories or optional
accessories, or from the use of non-origi-
nal wear parts or replacement parts.
The use of non-approved accessories,
optional accessories or non-genuine wear
parts / replacement parts (e.g. mains
cable) can have a negative effect in terms
of electrical safety and EMC.
2.8 Transport
The original packaging provides optimum protec-
tion for the unit during transport.
If required, original packaging for the unit can be
ordered from Dürr Dental.
Dürr Dental will not accept any responsi-
bility or liability for damage occurring dur-
ing transport due to the use of incorrect
packaging, even where the unit is still
under guarantee.
Only transport the unit in its original packaging.
Keep the packing materials out of the reach of
children.
Important information
6 9000-615-28L02 1903V004