6. Control Functions and Parameter Settings
6-17
Sequence Command
SE S3 S2 S1 S0
Selected
ramp time
OFF OFF OFF B41-0
B42-0
OFF OFF
ON
B41-1
B42-1
OFF
ON
OFF B41-2
B42-2
OFF
ON ON
B41-3
B42-3
ON
OFF OFF B41-4
B42-4
ON
OFF
ON
B41-5
B42-5
ON ON
OFF B41-6
B42-6
ON ON ON
B41-7
B42-7
Block-B parameters (S/W option constants) list
ApplicationNo. Parameter Unit Default Min. Max. Function
ST V/f VEC PM
B40 – Software option function
0 Function selection – 1 1 1. 4 = 1: Following functions are not used
= 2: Program ramp function
= 3: Pattern Run
= 4: Traverse run
1 Function selection – 2 1 1. 3 = 1: Following functions are not used
= 2: PID
= 3: PID, multi-pump control
B41 Program ramp acceleration
0
1
2
3
4
5
6
7
Acceleration time – 0
– 1
– 2
– 3
– 4
– 5
– 6
– 7
sec
sec
sec
sec
sec
sec
sec
sec
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
6000.0
6000.0
6000.0
6000.0
6000.0
6000.0
6000.0
6000.0
Select as follows with S0, S1, S2, S3
and SE.
B42 Program ramp – deceleration
0
1
2
3
4
5
6
7
Deceleration time – 0
– 1
– 2
– 3
– 4
– 5
– 6
– 7
sec
sec
sec
sec
sec
sec
sec
sec
20.0
20.0
20.0
20.0
20.0
20.0
20.0
20.0
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
6000.0
6000.0
6000.0
6000.0
6000.0
6000.0
6000.0
6000.0
The binary mode or
direct input mode is
selected with B11-8.
Sequence Command
SE S3 S2 S1 S0
Selected
ramp time
OFF OFF OFF OFF OFF Latest
values
OFF OFF OFF OFF
ON
B41-0
B42-0
OFF OFF OFF
ON
OFF B41-1
B42-1
OFF OFF
ON
OFF OFF B41-2
B42-2
OFF
ON
OFF OFF OFF B41-3
B42-3
ON
OFF OFF OFF OFF Latest
values
ON
OFF OFF OFF
ON
B41-4
B42-4
ON
OFF OFF
ON
OFF B41-5
B42-5
ON
OFF
ON
OFF OFF B41-6
B42-6
ON ON
OFF OFF OFF B41-7
B42-7
(1) For Binary mode selection (1) For Direct mode selection
SE and S3 are not used
When S0 to S3 are all OFF the latest ramp
time set value is hold. After power ON the
latest value is cleared to “0”