EasyManuals Logo
Home>Hypertherm>Welding System>XPR300

Hypertherm XPR300 User Manual

Hypertherm XPR300
438 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #197 background imageLoading...
Page #197 background image
Connect for Communication
4
XPR300 Instruction Manual 809480 197
Examples of output circuits
Logic interface, active high
Logic interface, active low
Relay interface
This circuit VOIDS the warranty. Do NOT use.
5VDC–24VDC
XPR
C
E
-
+
CNC/PLC
10 k (optional)
High-impedance (≤ 10 mA)
5VDC–24VDC
10 k (optional)
CNC/PLC
XPR
C
E
+
-
High-impedance (≤ 10 mA)
-
CNC +24 V
+24 V
CNC +24 V
XPR
E
C
J17
°t
+
Wire ground
CNC/PLC
External relay
24 VDC low-power coil
≤ 10 mA or ≥ 2400
All relay coils require a freewheeling diode across the relay
coil.
High-current contact closure
inputs (AC or DC)
Install a jumper
(108056)
XPR
Any voltage
C
E
+
-
Power ground

Table of Contents

Other manuals for Hypertherm XPR300

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm XPR300 and is the answer not in the manual?

Hypertherm XPR300 Specifications

General IconGeneral
BrandHypertherm
ModelXPR300
CategoryWelding System
LanguageEnglish

Related product manuals