Qualifications and Requirements
62 809480 Instruction Manual XPR300
Distance requirements between high-frequency leads and control cables
Electromagnetic interference (EMI) can occur if high-frequency leads (such as the pilot arc and
negative leads) are too close to control cables (such as the 120 VAC power, CAN, and EtherCAT
®
cables).
If possible, use a separate track to isolate each lead and cable.
If separate tracks are not possible, Hypertherm recommends a minimum separation distance
150 mm (6 inches) between the high-frequency leads and control cables. Separate the pilot arc
lead, negative lead, or any power cables that have a voltage higher than 120 VAC from the
following:
CAN cable
Power cable (120 VAC)
CNC lead (EtherCAT, serial RS-422, or discrete lead)
Distance requirements for ventilation and access
Ventilation
Do not block the ventilation louvers on the corners or bottom panels of the front and
back of the plasma power supply. A separation distance of least 1 m (3.3 feet) is
required for ventilation.
Do not block the ventilation louvers on the gas connect console. A separation distance
of least 1.27 cm (0.50 inch) is required for ventilation.
Do not block the ventilation louvers on the torch connect console. You must use the
mounting brackets to allow space between the console and mounting surface.
Service and maintenance access – Hypertherm recommends a minimum distance of
1 meter (3.3 feet) between the plasma power supply and other system components, or
between the plasma power supply and an obstacle.