Operation
226 809480 Instruction Manual XPR300
3. If none of the processes are satisfactory:
a. Select the closest available process.
b. Send the necessary offset command or commands to adjust the setting or settings as
necessary. Refer to Process ID offsets / overrides on page 226.
If you have an unusual process requirement, contact your cutting machine
supplier or regional Hypertherm Technical Service team for guidance.
Process ID offsets / overrides
You can adjust some pre-programmed settings with an offset or override command. An
offset/override command is a type of serial RS-422 or EtherCAT signal that lets you change the
default value of a setting, within an allowable limit.
For example, if a pre-programmed plasma pressure value is 65, and you want to change it to 70,
send an offset command of 5 (65 + 5 = 70). You can also use the web interface to send the desired
plasma pressure value (70). Refer to Web interface screen information on page 184.
Offset settings remain active until you send a new process ID to the
cutting system, or until power is removed from the cutting system.
For descriptions of offset commands and the allowable limits for each adjustable setting, refer to the
CNC Communication Protocol for the XPR Cutting System (809810).