Installation
3
124 809480 Instruction Manual XPR300
The following installation steps are for the VWI or OptiMix gas connect console.
If you have a Core gas connect console, refer to Connect supply gases to the gas connect
console (Core) on page 119.
Connect the supply gases
Table 21 Recommended sizes for gas fittings
NOTICE
INCORRECT GAS PRESSURES CAN CAUSE BAD PERFORMANCE
Gas leaks or pressure and flow rates that are outside of recommended ranges can:
Cause problems with system performance
Result in bad cut quality
Shorten the life of consumables
If the quality of the gas is bad or if the pressure setting is incorrect, it can decrease:
•Cut quality
Cut speed
Cut thickness capabilities
NOTICE
PTFE TAPE CAN CAUSE CLOGGED VALVES, REGULATORS, AND TORCHES
Never use PTFE tape on any joint preparation. Use only a liquid or paste thread sealant on male thread
ends.
Fitting type Size
N
2
/ Ar 5/8 inch 18 RH, internal (inert gas) “B”
Air 9/16 inch 19, JIC #6
F5 / H
2
9/16 inch 18, LH (fuel gas) “B”
O
2
9/16 inch RH (oxygen)

Table of Contents

Other manuals for Hypertherm XPR300

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm XPR300 and is the answer not in the manual?

Hypertherm XPR300 Specifications

General IconGeneral
BrandHypertherm
ModelXPR300
CategoryWelding System
LanguageEnglish

Related product manuals