Diagnostics and Troubleshooting
8
354 809480 Instruction Manual XPR300
Plasma power supply chopper PCB (141319)
LED Signal LED Signal
D22 +15V AND -15V POWER D1 DCA
D14 +5 V D2 DCB
D21 +3.3 V D3 STATUS
D32 OVER CURRENT CHANNEL B D4 ACTIVITY
D31 OVER CURRENT CHANNEL A D10 +5VB
D96 USBFLAG D33 CAN TX
D6 +18V AND -5V POWER D34 CAN RX
D22
D14
D21
D32
D31
D96
D1
D3
D4
D10
D33
D34
D6
D2