Table 3. Firmware Checkpoints (continued)
Checkpoint Description Action/ Possible Failing FRU
E5xy (E511 - E5FF)
Where x is not
equal to 0, and y is
not equal to 0.
Configure remote I/O subsystem
components
The E5xy (E511 to E5FF) codes are
reserved for activities relating to
configuration or testing of the I/O
subsystem, or remote I/O
subsystem. A hang at one of these
codes implies that a severe error
occurred during the programming of
I/O subsystem registers or when
interacting with adapters plugged
into the system. The last two digits
in the checkpoint can be used to
help isolate the location of the I/O
activity that caused the problem.
“x” indicates the I/O drawer number.
“y” indicates the PCI bus occurance.
If x=_, then the I/O drawer is:
X = I/O drawer
1=0
2=1
3=2
4=3
If y=_, then the PCI bus is:
Y = PCI bus
1=0
2=1
3=2
4=3
See “AIX and Physical Location
Code Reference Tables” on page 48
in Chapter 1, for location codes.
Using the information above, go to
“MAP 1540: Minimum Configuration”
on page 117.
E600 SSA PCI adapter Open firmware has
run successfully.
Replace the adapter. See note5 on
page 157 for location code
information related to this error.
E601 SSA PCI adapter BIST has started
but failed to complete after four
seconds.
Replace the adapter. See note 5 on
page 157 for location code
information related to this error.
E602 SSA PCI adapter Open firmware has
started.
Replace the adapter. See note 5 on
page 157 for location code
information related to this error.
E603 SSA PCI adapter BIST has
completed with an error.
Replace the adapter. See note 5 on
page 157 for location code
information related to this error.
154 Service Guide