Reference
Code
Description/Action
(Perform all actions before exchanging Failing
Items)
Failing Item
9284 Undefined status
Undefined status occurred during frame or STF
processing.
1. SPCN card assembly, R21
Location: U1.1-P2-X1
2. SPCN code problem
9285 BCC fault.
A BCC error was detected during network post
processing.
SPCN card assembly, R21
Location: U1.1-P2-X1
9286 Length check error.
Length check occurred during SPCN post
processing.
1. SPCN card assembly, R21
Location: U1.1-P2-X1
2. SPCN code problem
9287 Undefined status
Undefined status occurred during command
processing.
1. SPCN card assembly, R21
Location: U1.1-P2-X1
2. SPCN code problem
9288 Configuration error.
A configuration error was detected during system
frame processing.
1. SPCN card assembly, R21
Location: U1.1-P2-X1
2. SPCN code problem
9289 Invalid packet length for data sent.
Invalid packet length occurred for data
exchanged.
1. SPCN code problem
2. SPCN card assembly, R21
Location: U1.1-P2-X1
C512 ac box failure.
SPCN serial port communications fault occurred.
ac box
Location: U1.2-V7
C600 ac box failure.
The ac box control supply failed to turn off.
ac box
Location: U1.2-V7
C601 ac box failure.
ac box bus voltage control test fault occurred.
ac box
Location: U1.2-V7
C602 ac box failure.
ac box fault detection failure occurred.
ac box
Location: U1.2-V7
C609 Clock/processor regulator card failure
1. Clock/processor regulator card, M19
Location: U1.1-P1-X2
2. SPCN card R21
Location: U1.1-P2-X1
C62E SPCN network fault
An SPCN frame-to-frame communication failure
was detected.
1. ac box
Location: U1.2-V7
2. Go to “MAP 1520: Power” on page 88,
assume that you do not have an error code
when following the MAP.
1xxx
Chapter 5. Error Code to FRU Index 213