SOURce Subsystem
Query Syntax
[SOURce:]CURRent[:OVER]:PROTection[:LEVel]?
Returns
<NRf+>
12.10 [SOURce:]CURRent[:OVER]:PROTection:
DELay <NRf+>
This command is used to set the delay time of overcurrent protection.
Group
SOURce
Syntax
[SOURce:]CURRent[:OVER]:PROTection:DELay <NRf+>
Arguments
<NRf+>
MINimum|MAXimum|DEFault|<value>
Setting range: MIN to MAX
Default Value
None
Example
CURR:PROT:DEL 10
Query Syntax
[SOURce:]CURRent[:OVER]:PROTection:DELay?
Returns
<NRf+>