SOURce Subsystem
12.11 [SOURce:]VOLTage[:LEVel][:IMMediate][:
AMPLitude] <NRf+>
This command is used to set the input voltage value in CV operation mode.
Group
SOURce
Syntax
[SOURce:]VOLTage[:LEVel][:IMMediate][:AMPLitude] <NRf+>
Arguments
<NRf+>
MINimum|MAXimum|DEFault|<value>
Setting range: MIN to MAX
Default Value
None
Example
VOLT 5
Query Syntax
[SOURce:]VOLTage[:LEVel][:IMMediate][:AMPLitude]?
Returns
<NRf+>
12.12 [SOURce:]VOLTage:SLEW[:BOTH] <NRf+>
This command is used to set the voltage rise and fall time, that is, the two times
are set at the same time and take effect at the same time.
Group
SOURce
Copyright © Itech Electronic Co., Ltd.