BATTery Subsystem
14.2 BATTery:SHUT:TIME <NRf+>
This command is used to set the battery test cutoff time.
Group
BATTery
Syntax
BATTery:SHUT:TIME <NRf+>
Arguments
<NRf+>
MINimum|MAXimum|DEFault|<value>
Setting range: MIN to MAX
Default Value
DEFault: 20 s
Example
BATTery:SHUT:TIME 3
Query Syntax
BATTery:SHUT:TIME?
Returns
<NRf+>
MINimum|MAXimum|DEFault|<value>
14.3 BATTery:SHUT:VOLTage <NRf+>
This command is used to set the voltage value for the battery test cutoff.
Group
BATTery
Copyright © Itech Electronic Co., Ltd.