ARB Subsystem
Used to specify which step of the custom waveform, setting range: 1 to 200.
<NRf+>
MIN|MAX|<value>
Used to specify the time width of the present step, ranging from MIN to MAX.
Example
ARB:UDEFined:DWELl 2,3
Query Syntax
ARB:UDEFined:DWELl? <NR1>
Query by specifying a step number to return the time width corresponding to the
step in the LIST waveform.
Returns
<NRf+>
15.5 ARB:UDEFined:SLEW <NR1>,<NRf+>
This command is used to set the slope corresponding to the X step of the user-
defined waveform.
Group
ARB
Syntax
ARB:UDEFined:SLEW <NR1>,<NRf+>
Arguments
<NR1>
Used to specify which step of the custom waveform, setting range: 1 to 200.
<NRf+>
MIN|MAX|DEF|<value>
Used to specify the slope of the present step, in the range: MIN to MAX.
Copyright © Itech Electronic Co., Ltd.