127
KEB COMBIVERT F5-M / S
Name: Basis
12.05.04
Section PageDate
© KEB Antriebstechnik, 2002
All Rights reserved
Chapter
Functional DesriptionOperating and Unit Data
Adr.
min max
default
0032h
1
-
0
655350
Sy. 50 Control word
The control word is used for the status control of the inverter via bus. The control word long (Sy.43) consists of the two
16 bit parameters control word high (Sy.41) and Control word low (Sy.50). Das Steuerwort ist bitcodiert. The status word
is bit-coded. The description of the individual bits is found in Chapter 11.2.7.
Adr.
min max
default
0033h
1
-
0
655350
Sy. 51 Status word
With the status word the current condition of the inverter can be readout. The status word long (Sy.44) consists of the
two 16 bit parameters status word high (Sy.42) and status word low (Sy.51). Das Steuerwort ist bitcodiert. The status
word is bit-coded. The description of the individual bits is found in Chapter 11.2.7.
Adr.
min max
default
002Bh
1
-
0
2147483647-2147483648
Sy. 43 Control word long
The control word is used for the status control of the inverter via bus. The control word long (Sy.43) consists of the two
16 bit parameters control word high (Sy.41) and Control word low (Sy.50). The status word is bit-coded. The description
of the individual bits is found in Chapter 11.2.7.
Adr.
min max
default
002Ch
1
-
0
Sy. 44 Status word long
With the status word the current condition of the inverter can be readout. The status word long (Sy.44) consists of the
two 16 bit parameters status word high (Sy.42) and status word low (Sy.51). The status word is bit-coded. The description
of the individual bits is found in Chapter 11.2.7.
2147483647-2147483648
Adr.
min max
default
002Ah
1
-
0
655350
Sy. 42 Status word high
With the status word the current condition of the inverter can be readout. The status word long (Sy.44) consists of the
two 16 bit parameters status word high (Sy.42) and status word low (Sy.51). The status word is bit-coded. The description
of the individual bits is found in Chapter 11.2.7.