Parameter Description
This time delay allows the brake to release before the motor starts
turning. The drive will hold the speed command at zero, including
analog commands, for the adjusted time.
Unit: seconds
Value range: 0.0...3.0 s
Default setting: 0.3 s
Adjusted value: 0.3 s
Note: When the pre-torque function is active (LF.30 = 3 or 5),
the speed pick delay is the sum of the pre-torque ramp timers
US.17 and US.18. Proper adjustment of these timers will
automatically provide the required speed pick delay.
i
This time delays the release on the brake when the BRK output is
used in the brake control circuit.
Unit: seconds
Value range: 0.0...100.0 s
Default setting: 0.05 s
Adjusted value: 0.05 s
Speed Start Delay
Brake Release Delay