Estimated gear reduction
This parameter is read only and will change when adjustments
are made to LF.11, LF.20, LF.21 or LF.23.
This parameter can be used to estimate the gear ratio if it is not
known. After correctly entering values into LF.11, LF.20, LF.21,
and LF.23, read this value and then enter this value into LF.22.
Then to verify, run the car at inspection speed, measure the
actual speed with a hand tach. If the car speed is slower than the
adjusted inspection speed (LF.43), then increase LF.22. If it is
higher then the adjusted inspection speed, decrease LF.22.
Note: If LF.20 = 0.00 ft/min the value of LF.25 will be the same
as the last calculated value.
Unit: .01
Value range: 1.00...99.99
Parameter Description - Machine Data
Unit: 1
Value range: 1...8 (1:1...8:1)
Default setting: 1
Adjustment value: in accordance with the system data
Roping ratio
Load weight
Unit: pounds
Value range: 0...30000lbs
Default setting: 0 lb
Adjustment value: in accordance with the system

Table of Contents

Other manuals for KEB COMBIVERT F5

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KEB COMBIVERT F5 and is the answer not in the manual?

KEB COMBIVERT F5 Specifications

General IconGeneral
BrandKEB
ModelCOMBIVERT F5
CategoryDC Drives
LanguageEnglish

Related product manuals