137
Value of the internal function.
Units:%
This is the temperature of the output transistors.
Units: °C
Overload counter display. Once the load of the drive goes above 100% this counter
begins to increment. IF the load drops below it decrements. If the Counter reaches
100 the drive will shut down with an E.OL error.
Power On counter counts the time while powered up.
Units: hours
Run counter counts the time actual providing power to the motor and running the
elevator.
Units: hours
This is the percent utilization of the DC bus voltage. 100% means the DC bus
is 100% utilized and the output voltage is equal to the input voltage. If this value
reaches 100% or goes above 100% as a result of over modulation, loss of control
of the motor will occur.
Units: %
Displays the value of an internal timer.
Displays the value of an internal timer.
This is the actual carrier frequency the drive is operating at. Under certain conditions
the drive may lower the carrier frequency in order to provide more current at low
frequencies.
ru.38
Power module
temperature
ru.39
Overload
counter
ru.40
Power on
counter
ru.41
Run counter
ru.42
Modulation
grade
ru.43
Timer 1
ru.44
Timer 1
ru.45
Actual
switching
frequency
Diagnostic parameters
ru.37
Motor pot
value