133
Diagnostic parameters
ru.11
Commanded
torque
This is the internal torque command value which is fed into the current controller.
Units: Nm
This is the actual torque value which is calculated from the motor current.
Units: Nm
This is the load level of the inverter. 100% equals rated load.
Units: %
This is the peak load level of the inverter. 100% equals rated load. The highest
value is stored. The stored value can be reset by pressing the up or down key. It
will also reset when the power is turned off.
Units: %
This is the actual phase current  owing to the motor. The currents in the three
phases are averaged.
Units: Amps
This is the peak phase current. The highest value is stored. The stored value can
be reset by pressing the up or down key. It will also reset when the power is turned
off.
Units: Amps
This is the per phase value for the re ected rotor current. This current is the torque
producing component of the phase current and will be proportional to the torque.
Units: Amps
This is the actual value of the DC bus voltage. Normally it will be 1.4 times higher
than the input line voltage.
Units: Volts
Peak DC bus voltage. The highest value is stored. The stored value can be reset
by pressing the up or down key. It will also reset when the power is turned off.
Units: Volts
ru.12
Actual torque
ru.13
Actual load
ru.14
Peak load
ru.15
Phase current
ru.17
Torque current
ru.16
Peak current
ru.18
DC bus
voltage
ru.19
Peak DC
bus voltage