EasyManuals Logo
Home>KEB>DC Drives>COMBIVERT F5

KEB COMBIVERT F5 User Manual

KEB COMBIVERT F5
196 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #146 background imageLoading...
Page #146 background image
146
9.1 Digital Input Parameters
9.0 Input/Output Con guration
The digital input parameters can be used to con gure the digital
inputs for operation. Normally these parameters only need to be
adjusted by the Elevator control builder.
di. 0
Input Type
Determines whether the inputs are PNP (sourcing) or NPN (sinking). This setting
is applied globaly to all inputs.
Unit: -
Value Range: PnP, nPn
Default Setting: PnP
This parameter controls a digital noise  lter which can be used to mask relay bounce
or other unwanted momentary signals. This  lter applies to all digital inputs except
the enable input at X2A.16. The enable input is processed immediately.
Unit: mSec
Value Range: 0 ... 127 mSec
Default Setting: 5 mSec
di. 3
Noise Filter

Table of Contents

Other manuals for KEB COMBIVERT F5

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KEB COMBIVERT F5 and is the answer not in the manual?

KEB COMBIVERT F5 Specifications

General IconGeneral
BrandKEB
ModelCOMBIVERT F5
CategoryDC Drives
LanguageEnglish

Related product manuals