Parameter Description - Basic Set Up
This parameter displays the current mode of operation, open or closed
loop, geared or gearless, induction motor, synchronous motor. The
parameter is read only.
Possible displays:
ICLSd = Closed loop induction
I9LSS = Closed loop induction gearless
PCLSd = Closed loop permanent magnet
P9LSS = Closed loop permanent magnet gearless
With LF. 5 all drive faults can be automatically reset.
The number adjusted in this parameter determines how many times
per hour the elevator drive will automatically reset faults. Before
resetting the fault, the drive will wait 4 seconds to allow everything
to stop or stabilize. It is not fault speciī˜‚ c, so with the default setting
of 5, if the drive experiences 6 different faults in one hour the unit
will latch the last fault and not reset. See parameter LF.98 for fault
history information.
Unit: 1
Value range: 0...10
Default setting: 5
Drive fault auto reset
Selected motor
Note: a setting of ā€œ0ā€
means no fault resets.

Table of Contents

Other manuals for KEB COMBIVERT F5

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KEB COMBIVERT F5 and is the answer not in the manual?

KEB COMBIVERT F5 Specifications

General IconGeneral
BrandKEB
ModelCOMBIVERT F5
CategoryDC Drives
LanguageEnglish

Related product manuals