IEEE-488 Reference
5-95
5.16
:STATus Subsystem
The status subsystem is used to control the status registers of the Model 7001. These registers and the overall status structure
are explained in paragraph 5.6.
The commands in this subsystem are summarized in Table 5-11.
Table 5-11
STATus command summary
Command Description Reference
:STATus
:OPERation
[:EVENt]?
:ENABle <NRf>
:ENABle?
:PTRansition <NRf>
:PTRansition?
:NTRansition <NRf>
:NTRansition?
:CONDition?
:ARM
[:EVENt]?
:ENABle <NRf>
:ENABle?
:PTRansition <NRf>
:PTRansition?
:NTRansition <NRf>
:NTRansition?
:CONDition?
:SEQuence
[:EVENt]?
:ENABle <NRf>
:ENABle?
:PTRansition <NRf>
:PTRansition?
:NTRansition <NRf>
:NTRansition?
:CONDition?
:TRIGger
[:EVENt]?
:ENABle <NRf>
:ENABle?
:PTRansition <NRf>
:PTRansition?
:NTRansition <NRf>
:NTRansition?
:CONDition?
:QUEStionable
[:EVENt]?
:ENABle <NRf>
:ENABle?
Path to control operation event registers:
Query event register.
Program the enable register.
Query enable register.
Program the positive transition register.
Query positive transition register.
Program the negative transition register.
Query negative transition register.
Query condition register.
Path to control arm event registers:
Query event register.
Program the enable register.
Query enable register.
Program the positive transition register.
Query positive transition register.
Program the negative transition register.
Query negative transition register.
Query condition register.
Path to control the sequence event registers:
Query event register.
Program the enable register.
Query enable register.
Program the positive transition register.
Query positive transition register.
Program the negative transition register.
Query negative transition register.
Query condition register.
Path to control trigger event registers:
Query event register.
Program the enable register.
Query enable register.
Program the positive transition register.
Query positive transition register.
Program the negative transition register.
Query negative transition register.
Query condition register.
Path to control questionable event registers:
Query the event register.
Program the enable register.
Query the enable register.
5.16.1
5.16.2
5.16.3
5.16.4
5.16.5
5.16.1
5.16.2
5.16.3
5.16.4
5.16.5
5.16.1
5.16.2
5.16.3
5.16.4
5.16.5
5.16.1
5.16.2
5.16.3
5.16.4
5.16.5
Artisan Scientific - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisan-scientific.com

Table of Contents

Other manuals for Keithley 7001

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keithley 7001 and is the answer not in the manual?

Keithley 7001 Specifications

General IconGeneral
BrandKeithley
Model7001
CategorySwitch
LanguageEnglish

Related product manuals