- 102 -
KD 702_1003_1404 Workshop Manual_cod. ED0053029340_1° ed_ rev. 00
210
212
211
11
209
7000
2400
100
460
-20
0
+20
+40
23,5÷29,5
13,5÷16,5
8,5÷10,5
6,0÷8,0
4,0÷7,0
≤ 320 +50
Pre-heating plug control unit with coolant temperature
sensor
To avoid white smoke immediately following start-up post-heat
for about 5 seconds, see table
For electrical connections see gures 196-199-203.
Pre-heating glow plug
Characteristics:
Nominal voltage
................................ 12,5V
Current absorption ............................ 12A÷14A after 5 seconds
Sheath surface temperature .............850°C after 5 seconds.
Components:
1 Sheath
2 Primary Heating Coil
3 Secondary Heating Coil
When remounting tighten at a torque of 20 Nm.
Post-heat
Glow-plug heat time
(sec.)
Pre-heat
Coolant temp.
°C
Resistance
(ohm)
Thermistor input
Heating stop
Starter motor, Bosch DW 12V 1,6 KW - Performance Curve
The curve was obtained at room temperature of -20°C with a fully
charged 88 Ah battery.
U
= Starter Motor Voltag
n = Armature r/min
I = Absorbed Amperage
P = Starter Output Power (KW)
M = Starter Output Torque (Nm)
Electric System