- 109 -
KD 702_1003_1404 Workshop Manual_cod. ED0053029340_1° ed_
13
Storage
PREPARING THE ENGINE FOR OPERATION AFTER PROTECTIVE TREATMENT
After the storage period and before starting up the engine and preparing it for operation, you need to perform certain operations
to ensure maximal efciency conditions.
1 -
Remove the protective sheet.
2 - Remove any sealing devices from the exhaust and intake ducts.
3 - Use a cloth soaked in degreasing product to remove the protective treatment from the external parts.
5 - Inject lubricating oil (no more than 2 cm3) into the intake ducts.
6 - Adjust the alternator/fan belt tension.
7 - Turn the engine manually to check the correct movement and smoothness of the mechanical parts.
8 - Rell the tank with fresh fuel.
9 - Make sure that the oil and the coolant are up to the maximum level.
10 - Start the engine and after some minutes bring it to ¾ of the maximum speed for 5-10 minutes.
11 - Turn off the engine.
12 - Remove the oil drain plug (see “Oil replacement”) and discharge the AGIP RUSTIA NT protective oil while the engine is hot.
13 - Pour new oil (see "Table of lubricants") up to the maximum level.
14 - Replace the lters (air, oil, fuel) with original spare parts.
15 - Empty the cooling circuit completely and pour in the new coolant up to the maximum level.
Caution - Warning
Over time, a number of engine components and lubricants lose their properties, so it is important considering
whether they need replacing, also based on age (see Replacement table).
Important
Maximum every 24 months of inactivity, the engine must be started up by repeating all "Engine Storage"
operations.