STORAGE
- When the engines are not for more than 6 months, they have to be protected performing the operations described in
the following pages.
- If the engine is not to be used for extensive periods, check the storage area conditions and the type of packaging and
make sure that these are suitable for correct storage.
If necessary, cover the engine with a proper protective sheet.
- Avoid storing the engine in direct contact with the ground, in environments that are humid and exposed to bad weather,
near high voltage electric lines, etc.
Important
If, after the rst 6 months, the engine is still not used, it is necessary to carry out a further measure to extend
the protection period (see “Protective treatment”).
1 -
Pour in the engine housing AGIP RUSTIA C protective oil up to the maximum level.
2 - Fill up with fuel containing 10% AGIP RUSTIA NT.
3 - Make sure that the coolant is up to the maximum level.
4 - Start the engine and keep it idle at minimum speed for some minutes.
5 - Bring the engine to ¾ of the maximum speed for 5÷10 minutes.
6 - Turn off the engine.
7 - Empty out completely the fuel tank.
8 - Spray SAE 10W on the exhaust and intake manifolds.
9 - Seal the exhaust and intake ducts to prevent foreign bodies from entering.
10 - Thoroughly clean all external parts of the engine using suitable products.
11 - Treat non-painted parts with protective products (AGIP RUSTIA NT).
12 - Loosen the alternator/fan belt.
13 - Cover the engine with a proper protective sheet.
Caution - Warning
In countries in which AGIP products are not available, nd an equivalent product (with specications: MIL-L-
21260C).
Important
Maximum every 24 months of inactivity, the engine must be started up by repeating all "Engine Storage"
operations.
ENGINE STORAGE
PROTECTIVE TREATMENT