18 GV 640 Service Manual
For internal use only
4.7 Removing the control panel
This is only possible if the outer door (if present) is removed.
Preparation
1. Remove the cables on the left and right
from their sockets.
2. Remove the cable for the rinse aid refill
sensor.
3. Remove the earth cable.
Removal
1. Open the door.
2. Remove the top 6 screws.
3. Remove the control panel.
Installation
1. Fix the control panel onto the inner door
and then fasten the 6 screws.
2. Reconnect the plug connections.
Please note!
Hold the control panel with one
hand when you take out the last
screw. The panel is not secured
by more than the screws and may
fall down. Use 4x16 mm screws.