GV 640 Service Manual 41
For internal use only
6.1.11 Installing the zeolite container when the rinsing cavity is installed
The procedure is as follows if the blow-out cap is accidentally opened or if the zeolite container is only
fastened after the cavity has been put in place:
1. Carefully lever up the zeolite container
slightly with the help of a wide screwdriver.
2. Install the blow-out cap carefully and uni-
formly onto the blow-out opening of the zeo-
lite container and turn it clockwise until it
stops and is secure.
6.1.12 Replacing the zeolite auxiliary module
This is only possible if the base panel and the base sheet have been removed.
Dismounting
1. Loosen the screw and pull the module out of
the appliance towards the front.
2
Please note!
Lower spray arm
After final assembly a check will
need to be made to ensure that the
lower spray arm can move unham-
pered and does not get stuck on the
cap.