Commissioning
Adjusting the motor
Motor temperature monitoring with PTC or thermal contact
6
6.6
6.6.3
6.6-8
EDSVF9333V EN 3.0-06/2005
Motor dataInformationonthemotor
nameplate
C0076C0075C0071C0070C0091C0090C0089C0088C0087C0085C0084C0081C0022C0086Field
T
ni
V
pi
T
nn
V
pn
cos ϕU
r
[V]
f
r
[Hz]
IN
[A]
n
N
[rpm]
Lσ
[mH]
R
s
[Ω]
P
r
[kW]
Imax
[A]
TypeC86
1089 MDEBAXM-080-12 252 4.16 0.95 20.69 89.00 2510 2.77 87 400 0.68 6 300 1.6 2
1090 MDEBAXM-080-32 213 3.00 0.75 11.69 65.20 1400 2.00 50 400 0.72 6 300 3.5 2
1091 MDEBAXM-080-32 253 5.20 1.30 11.69 65.20 2510 3.46 87 400 0.72 6 300 1.9 3
1092 MDEBAXM-090-12 214 4.05 1.10 6.40 37.00 1420 2.70 50 400 0.77 6 300 2.5 2
1093 MDEBAXM-090-12 254 7.05 2.00 6.40 37.00 2535 4.70 87 400 0.77 6 300 2 2
1094 MDEBAXM-090-32 215 5.40 1.50 4.80 26.00 1415 3.60 50 400 0.77 6 300 2 2
1095 MDEBAXM-090-32 255 9.30 2.70 4.80 26.00 2530 6.20 87 400 0.77 6 300 1 2
1096 MDEBAXM-100-12 216 7.20 2.20 2.90 20.00 1425 4.80 50 400 0.80 6 300 1 1.5
1097 MDEBAXM-100-12 256 12.45 3.90 2.90 20.00 2535 8.30 87 400 0.80 6 300 0.8 1.5
1098 MDEBAXM-100-32 217 9.90 3.00 2.10 17.00 1415 6.60 50 400 0.81 6 300 2.5 1.5
1099 MDEBAXM-100-32 257 17.10 5.35 2.10 17.00 2530 11.40 87 400 0.81 6 300 1.4 1.8
1100 MDEBAXM-112-22 218 12.45 4.00 1.50 11.00 1435 8.30 50 400 0.82 6 300 2 2
1101 MDEBAXM-112-22 258 21.45 7.10 1.50 11.00 2545 14.30 87 400 0.82 6 300 1 2
1102 MDEBAXM-112-32 219 17.85 5.50 2.71 21.40 1425 11.90 50 400 0.84 6 300 1.5 10
1114 MDFMAxx-200-32 224 83.25 30.00 1465 55.50 50 400 0.85 6 300 1 2
1115 MDFMAxx-200-32 264 145.50 52.00 2575 97.00 87 400 0.85 6 300 1 2
6.6.3 Motor temperature monitoring with PTC or thermal contact
PTC resistors can be connected via the terminal inputs T1 and T2 according
to DIN 44081 and DIN 44082. The motor temperature is measured and
integrated into the drive monitoring.
A thermal contact (NC contact) can also be connected to T1 and T2. Lenze
three-phase AC motors provide this as default.
When using motors equipped with PTC resistors or thermostats, we
recommend to always activate the PTC input. This prevents the motor from
being destroyed by overheating.
Stop!
ƒ The motor temperature monitoring may only be connected to
T1, T2 if the cable is terminated with a PTC or thermal contact
(NC contact) on the motor side.
An ”open” cable acts like an antenna and can cause faults at
the drive controller.
Input signals at T1, T2 are processed with a delay of 2 s.
ƒ The drive controller can only evaluate a PTC resistor! Do not
connect several PTC resistors in series or in parallel:
The motor temperature would be measured incorrectly.
The motors could be destroyed by overheating.
ƒ If you operated several motors on a drive controller, use
thermal contacts (NC contacts) for motor temperature
monitoring and connect these in series.
ƒ To achieve full motor protection, an additional temperature
monitoring with separate evaluation must be installed.
Description