Configuration
Code table
8
8.3
8.3-63
EDSVF9333V EN 3.0-06/2005
IMPORTANTPossible settingsCode
SelectionLenzeNameNo.
C0988 Input signals -199.99 {0.01 %} 199.99
Function block MFAIL
z Display of the signals linked in
C0970, C0973, C0974, C0975,
C0976, C0977 and C0978
See System
Manual
(extension)
1 DIS: N-SET
2 DIS: ADAPT
3 DIS: CONST
4 DIS: THRESHLD
5 DIS: NACT
6 DIS: SET
7 DIS: DC-SET
C0989 0 1
Function block MFAIL
z Display of the signals linked in
C0971 and C0972
1 DIS: FAULT
2 DIS: RESET
C1000 DIVISION 1 0 {1} 31
Part factor, function block
CONVPHA1
z Calculate output signal:
See System
Manual
(extension)
OUT [%] = IN [%] ⋅
100 %
2
14
⋅ 2
C1000
C1001
CFG: IN 1000 FIXED0INC Selection list 3 Configuration of input signal,
function block CONVPHA1
C1002 DIS: IN -2147483648 {1} 2147483647 Function block CONVPHA1
z Display of the signal linked in
C1001
C1040 Acceleration 100.00
0
0.001 {0.001 } 5000.000 Acceleration, function block
SRFG1
z Max. acceleration
See System
Manual
(extension)
C1041 JERK 0.200 0.001 {0.001
s}
999.999 Jerk, function block SRFG1
z S-ramp time
C1042
CFG: IN 1000 FIXED0% Selection list 1 Configuration of analog input
signal, function block SRFG1
C1043
CFG: SET 1000 FIXED0% Selection list 1 Configuration of analog input
signal, function block SRFG1
z Starting value for the ramp
function generator
z Starting value is accepted
when SRFG1-LOAD = HIGH
C1044
CFG: LOAD 1000 FIXED0 Selection list 2 Configuration of digital input
signal, function block SRFG1
z HIGH = accepts the value at
SRFG1-SET and outputs it to
SRFG1-OUT. SRFG1-DIFF
remains on 0 %
C1045 -199.99 {0.01 %} 199.99
Function block SRFG1
z Display of the signals linked in
C1042 and C1043
1 DIS: IN
2 DIS: SET
C1046 DIS: LOAD 0 1 Function block SRFG1
z Display of the signal linked in
C1044
C1090 Output signal -2147483648 {1} 2147483647 Function block FEVAN1
z Display of the converted signal
See System
Manual
(extension)
C1091 Code 141 2 {1} 2000 Code, function block FEVAN1
z Selection of the target code in
which the calculated value is
to be written
C1092 Subcode 0 0 {1} 255 Subcode, function block FEVAN1
z Selection of the target subcode
in which the calculated value is
to be written