EasyManuals Logo
Home>Lenze>DC Drives>EVF9327

Lenze EVF9327 User Manual

Lenze EVF9327
459 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #183 background imageLoading...
Page #183 background image
Commissioning
Operating mode
V/f characteristic control
6
6.8
6.8.1
6.8-4
EDSVF9333V EN 3.0-06/2005
6.8.1 V/f characteristic control
The output voltage of the controller follows a defined characteristic. At low
output frequencies, the characteristic can be boosted. It can be adapted to
different load profiles.
ƒ Linear characteristic for drives with constant load torque over the
speed.
ƒ Quadratic characteristic for drives with quadratic load torque over the
speed:
Quadratic V/f characteristics are preferably used in centrifugal pump
and fan drives. However, it must be checked whether your pump or
fan drive can be operated in this operating mode!
–Ifyourpumporfandrivecannotbeusedfortheoperationwitha
quadratic V/f characteristic, the linear V/f characteristic or vector
control mode must be used.
01
0
C0089
C0090
100 %
N
n
n
U
min
U
out
01
0
C0089
C0090
100 %
N
n
n
U
min
U
out
9300vec085 9300vec086
Fig. 6.8-3 Linear and square-law V/f characteristic
Codes for parameter setting
Code Possible settings IMPORTANT
No. Name Lenze Selection
C0006
OP MODE 5
Selection of the operating mode
forthemotorcontrol
1 vector ctrl Vector control
without or with
speed feedback
In case of the first selection enter
the motor data and identify them
with C0148.
6.8-8
5 V/f V/f characteristic
control
Commissioning without
identification of the motor data is
possible
z Advantage of identification
with C0148: Improved smooth
running at low speeds
6.8-4
C0014 V/f charact. 0
Characteristic in the V/f
characteristic control mode
8.2-25
0 Linear Linear V/f characteristic
1 square Square V/f characteristic
C0015 Rated freq 50 10 {1 Hz} 5000 V/f-rated frequency
In C0015 you can set a base
frequency which differs from the
rated motor frequency (C0089)
z Lenze setting: C0015 = C0089
z Changing C0086 or C0089
overwrites the value in C0015
8.2-25
Description

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze EVF9327 and is the answer not in the manual?

Lenze EVF9327 Specifications

General IconGeneral
BrandLenze
ModelEVF9327
CategoryDC Drives
LanguageEnglish