Technical data
Operation with rated power (normal operation)
Rated data for 400 V mains voltage
3
3.2
3.2.1
3.2-1
EDSVF9333V EN 3.0-06/2005
3.2 Operation with rated power (normal operation)
3.2.1 Rated data for 400 V mains voltage
Typical motor power
Three-phase asynchronous motor
(4-pol.)
P
r
[kW] 0.37 0.75 1.5 3.0
P
r
[hp] 0.5 1.0 2.0 4.0
9300 vector type EVF9321 EVF9322 EVF9323 EVF9324
Mains voltage U
mains
[V] 3/PE AC 320 V - 0 % ... 528 V + 0 % ; 45 Hz - 0 % ... 65 Hz + 0 %
Alternative DC supply U
DC
[V] DC 460 V - 0 % ... 620 V + 0 %
Data for operation on 3/PE AC 400 V or DC 565 V
Rated mains current
Without mains choke/mains filter I
mains
[A] 2.1 3.5 5.5 –
With mains choke/mains filter I
mains
[A] 1.5 2.5 3.9 7.0
Output power U, V,
W with switching
frequency
2and4kHz
S
N
[kVA] 1.0 1.7 2.7 4.8
8kHz
S
N
[kVA] 1.0 1.7 2.7 4.8
Output power +U
DC
,-U
DC
1)
P
DC
[kW] 1.9 0.7 0.0 2.0
Rated output current
with switching
frequency
2and4kHz
4)
I
r
[A] 1.5 2.5 3.9 7.0
8kHz I
r
[A] 1.5 2.5 3.9 7.0
8kHzsin I
r
[A] 1.5 2.5 3.9 7.0
16 kHz I
r
[A] 1.1 1.8 2.9 5.2
8/2 kHz
3)
I
r
[A] 1.5 2.5 3.9 7.0
Max. permissible
output current for 60
s at a switching
frequency
2) of
2and4kHz I
max
[A] 2.2 3.7 5.8 10.5
8kHz I
max
[A] 2.2 3.7 5.8 10.5
8kHzsin I
max
[A] 2.2 3.7 5.8 10.5
16 kHz I
max
[A] 1.6 2.7 4.3 7.8
8/2 kHz
3)
I
max
[A] 2.2 3.7 5.8 10.5
Output voltage
Without mains choke/mains filter U
M
[V] 3~0...U
mains
/ 0 ... 600 Hz
With mains choke/mains filter U
M
[V] 3~0...approx.94%U
mains
/ 0 ... 600 Hz
Power loss (operation with I
N
) P
v
[W] 50 65 100 150
Required mains choke Type – – –
ELN3-0250H007
Dimensions
H [mm] 350 350 350 350
b [mm] 78 78 97 97
T [mm] 250 250 250 250
Earth [kg] 4.9 4.9 5.8 6.0
Bold print = Lenze setting
1)
Power supplied by the DC bus when operating with power-adapted motor
2)
Currents for periodic load change: 60 s of overcurrent time with I
max
and 120 s of base load time
with 75 % I
N
3)
Power-optimised operation with automatic switching frequency reduction. When the max.
permissible output c urrent is exceeded, the switching frequency is reduced to 2 kHz.
4)
Possible for some types in case of other operating conditions: Operation with increased rated
output current at the same load change (see chapter ”Operation with increased rated power”)