Configuration
Code table
8
8.3
8.3-42
EDSVF9333V EN 3.0-06/2005
IMPORTANTPossible settingsCode
SelectionLenzeNameNo.
C0705 Function 1
1 IN1=IN2
Function selection, function block
CMP4
z Compare input signals at
CMP4-IN1 and CMP4-IN2
See System
Manual
(extension)
2 IN1>IN2
3 IN1<IN2
4 |IN1| = |IN2|
5 |IN1| > |IN2|
6 |IN1| < |IN2|
C0706 HYSTERESIS 1.00 0.00 {0.01 %} 100.00 Hysteresis, function block CMP4
z Hysteresis for input signals
which are not stable and hence
the output oscillates
C0707 Window 1.00 0.00 {0.01 %} 100.00 Window, function block CMP4
z Set the range in which the
signal comparison is to be
apply
C0708
Selection list 1 Configuration of analog input
signal, function block CMP4
1 CFG: IN 1000 FIXED0% CMP4-IN1
2 CFG: IN 1000 FIXED0% CMP4-IN2
C0709 -199.99 {0.01 %} 199.99 Function block CMP4
z Display of the signals linked in
C0708
1 DIS: IN CMP4-IN1
2 DIS: IN CMP4-IN2
C0710 Function 0
Function selection, function block
TRANS1
See System
Manual
(extension)
0 Rising trans Rising edge 1. LOW-HIGH edge at TRANS1-IN
switches TRANS1-OUT = HIGH
2. After the time has elapsed
(C0711),
TRANS1-OUT switches to LOW
1 Falling trans Falling edge 1. HIGH-LOW edge at TRANS1-IN
switches TRANS1-OUT = HIGH
2. After the time has elapsed
(C0711),
TRANS1-OUT switches to LOW
2 Both trans Both edges 1. LOW-HIGH- or HIGH-LOW
edge at TRANS1-IN switches
TRANS1-OUT = HIGH
2. After the time has elapsed
(C0711),
TRANS1-OUT switches to LOW
C0711 Pulse T 0.001 0.001 {0.001
s}
60.000 Pulse duration, function block
TRANS1
z After the time has elapsed,
TRANS1-OUT switches to LOW
C0713
CFG: IN 1000 FIXED0 Selection list 2 Configuration of digital input
signal, function block TRANS1
C0714 DIS: IN 0 1 Function block TRANS1
z Display of the signal linked in
C0713