Wiring the standard device
Basic devices in the power range 15 ... 30 kW
Important notes
5
5.5
5.5.2
5.5-3
EDSVF9333V EN 3.0-06/2005
5.5.2 Important notes
To gain access to the power connections, remove the cover:
Remove the cover of the drive controller
0
1
1. Remove the screws
2. Lift cover up and detach it
9300vec113
Installation material required from the scope of supply:
Description Use Amount
Hexagon nut M6 (DIN 934) Connection of supply cables (mains, +U
G
,-U
G
)
and motor cable to the stud bolts
10
Washer ∅ 6 mm (DIN 125) For hexagon nut M6 10
Spring washer ∅ 6 mm (DIN 127) For hexagon nut M6 10
Grommet Motor cable 1
Shield connection support Support of the shield sheet for motor cable 1
Self-tapping screw ∅ 4×14mm Fastening of shield connection support 2
Shield sheet Shield connection for motor cable 1