EasyManuals Logo
Home>Lenze>DC Drives>EVF9327

Lenze EVF9327 User Manual

Lenze EVF9327
459 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #195 background imageLoading...
Page #195 background image
Commissioning
Acceleration, deceleration, braking, stopping
Speed range
6
6.10
6.10.1
6.10-2
EDSVF9333V EN 3.0-06/2005
Features of ”maximum output frequency” (n
max
):
ƒ When selecting fixed setpoints (JOG), C0011 acts as limitation.
ƒ C0011 is an internal scaling variable! Therefore m ajor changes may
only be carried out when the controller is inhibited!
Stop!
Set 0011 so that the maximum permissible motor speed is not
exceeded.
Otherwise the motor will be destroyed.
The internal speed limits must be observed (p = number of motor pole pairs):
ƒ Switching frequency 16 kHz: n
max
= 36000/p min
-1
ƒ Switching frequency 8 kHz: n
max
= 36000/2p min
-1
ƒ Switching frequency 2/4 kHz: n
max
= 36000/4p min
-1
C0011
Setting tips

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze EVF9327 and is the answer not in the manual?

Lenze EVF9327 Specifications

General IconGeneral
BrandLenze
ModelEVF9327
CategoryDC Drives
LanguageEnglish

Related product manuals