Configuration
Code table
8
8.3
8.3-64
EDSVF9333V EN 3.0-06/2005
IMPORTANTPossible settingsCode
SelectionLenzeNameNo.
C1093 Numerator 1.0000 0.0001 {0.0001} 100000.0000 Numerator, function block
FEVAN1
z Scaling of the input signal
See System
Manual
(extension)
C1094 Denominator 0.0001 0.0001 {0.0001} 100000.0000 Denominator, function block
FEVAN1
z Scaling of the input signal
C1095 offset 0 0 {1} 1000000000 Offset, fu nction block FEVAN1
z An offset can be added to the
converted signal
C1096
CFG: IN 1000 FIXED0% Selection list 1 Configuration of analog input
signal, function block FEVAN1
See System
Manual
(extension)
C1097
CFG: LOAD 1000 FIXED0 Selection list 2 Configuration of digital input
signal, function block FEVAN1
z ALOW-HIGHedgetransmits
the converted signal to the
target code
C1098 DIS: IN -32768 {1} 32767 Function block FEVAN1
z Display of the signal linked in
C1096
See System
Manual
(extension)
C1099 DIS: LOAD Function block FEVAN1
z Display of the signal linked in
C1097
C1100 Function 1
Function selection, function block
FCNT1
See System
Manual
(extension)
1 Return |FCNT1-OUT| ≥ |FCNT1-CMP-VAL|:
z The numerator is reset to the
value at FCNT1-LD-VAL
2 Hold |FCNT1-OUT| = |FCNT1-CMP-VAL|:
z The numerator is stopped
C1101
Selection list 1 Configuration of analog input
signals, function block FCNT1
See System
Manual
(extension)
1 CFG: LD-VAL 1000 FIXED0% z Starting value
2 CFG: CMP-VAL 1000 FIXED0% z Comparison value
C1102
Selection list 2 Configuration of digital input
signals, function block FCNT1
See System
Manual
(extension)
1 CFG: CLKUP 1000 FIXED0 LOW-HIGH edge counts upwards
by one
2 CFG: CLKDWN 1000 FIXED0 LOW-HIGH edge counts
downwards by one
3 CFG: LOAD 1000 FIXED0 z HIGH = accepts starting value
z Input signal has highest
priority
C1103 -32768 {1} 32768
Function block FCNT1
z Display of the signals linked in
C1101
See System
Manual
(extension)
1 DIS: LD-VAL
2 DIS: CMP-VAL
C1104 0 1
Function block FCNT1
z Display of the signals linked in
C1102
1 DIS: CLKUP
2 DIS: CLKDWN
3 DIS: LOAD