EasyManuals Logo
Home>Lenze>DC Drives>EVF9327

Lenze EVF9327 User Manual

Lenze EVF9327
459 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #35 background imageLoading...
Page #35 background image
Technical data
Operation with rated power (normal operation)
Rated data for 480 V mains voltage
3
3.2
3.2.2
3.2-6
EDSVF9333V EN 3.0-06/2005
Typical motor power
Three-phase asynchronous motor
(4-pol.)
P
r
[kW] 37 55 75 90 110
P
r
[hp] 49.5 74 100 120 148
9300 vector type EVF9329 EVF9330 EVF9331 EVF9332 EVF9333
Mains voltage U
mains
[V] 3/PE AC 320 V - 0 % ... 528 V + 0 % ; 45 Hz - 0 % ... 65 Hz + 0 %
Alternative DC supply U
DC
[V] DC 460 V - 0 % ... 740 V + 0 %
Data for operation on 3/PE AC 480 V or DC 678 V
Rated mains current
Without mains choke/mains filter I
mains
[A]
With mains choke/mains filter I
mains
[A] 55.0 80.0 100 135 165
Output power U, V,
W with switching
frequency
2and4kHz
S
N
[kVA] 49.9 69.8 91.4 124 158.2
8kHz
S
N
[kVA] 49.9 69.8 91.4 124 149
Output power +U
DC
,-U
DC
1)
P
DC
[kW] 0.0 5.9 0.0 32.4 47.1
Rated output current
with switching
frequency
2and4kHz I
r
[A] 56.0 84.0 105 142 171
8kHz I
r
[A] 56.0 84.0 105 142 141
8kHzsin I
r
[A] 44.0 55.0 71.0 87.0 94.0
16 kHz I
r
[A] 33.0 43.7 49.5 55.0 59.0
8/2 kHz
3)
I
r
[A] 56.0 84.0 105 142 171
Max. permissible
output current for 60
s at a switching
frequency
2) of
2and4kHz I
max
[A] 84.0 126 157 213 256
8kHz I
max
[A] 84.0 126 157 213 211
8kHzsin I
max
[A] 66.0 82.0 107 130 141
16 kHz I
max
[A] 49.0 65.6 74.0 83.0 89.0
8/2 kHz
3)
I
max
[A] 84.0 126 157 213 256
Output voltage
With mains choke/mains filter U
M
[V] 3~0...approx.94%U
mains
/ 0 ... 600 Hz
Power loss (operation with I
N
) P
v
[W] 810 1100 1470 1960 2400
Required mains choke Type
ELN3-0055H055 ELN3-0038H085 ELN3-0027H105 ELN3-0022H130 ELN3-0017H170
Dimensions
H [mm] 350 510 591 680 680
b [mm] 250 340 340 450 450
T [mm] 250 285 285 285 285
Earth [kg] 18.0 36.0 38.0 70.0 70.0
Bold print = Lenze setting
1)
Power supplied by the DC bus when operating with power-adapted motor
2)
Currents for periodic load change: 60 s of overcurrent time with I
max
and 120 s of base load time
with 75 % I
N
3)
Power-optimised operation with automatic switching frequency reduction. When the max.
permissible output c urrent is exceeded, the switching frequency is reduced to 2 kHz.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze EVF9327 and is the answer not in the manual?

Lenze EVF9327 Specifications

General IconGeneral
BrandLenze
ModelEVF9327
CategoryDC Drives
LanguageEnglish

Related product manuals