Configuration
Code table
8
8.3
8.3-36
EDSVF9333V EN 3.0-06/2005
IMPORTANTPossible settingsCode
SelectionLenzeNameNo.
C0594 MONIT SD6 3
0 TRIP
Activation of the motor
temperature monitoring with
KTY at X8
z UseC0594=0or2toactivate
monitoring
z In case of a short circuit or
interruption at X8/5 and X8/8
the fault message SD6 is
activated
z Configuration of the response
when exceeding the motor
temperature
– Fixed operating temperature
in C0583
– Variable operating
temperature in C0584
6.6-10
See System
Manual
(extension)
2 Warning
3 Off
C0595 MONIT CE4 3
0 TRIP
Configuration of monitoring CE4,
BUS-OFF (system bus)
See System
Manual
(extension)
2 Warning
3 Off
C0596 N
max
limit 4000 0 {1 rpm} 36000 Configuration of monitoring
N
max
, maximum system speed
exceeded
See System
Manual
(extension)
C0597 MONIT LP1 3
0 TRIP
Configuration of monitoring the
motor phases LP1
See System
Manual
(extension)
2 Warning
3 Off
C0598 MONIT SD5 3
0 TRIP
Configuration of monitoring SD5,
open circuit at analog input X6/1,
X6/2
See System
Manual
(extension)
2 Warning
3 Off
C0599 Limit LP1 5.0 1.0 {0.1 %} 10.0 Configuration of current limit
LP1, current limit value for
monitoring the motor phases in
C0597
See System
Manual
(extension)
C0600 Function 1
0 OUT = IN1
Function selection, function block
ARIT2
See System
Manual
(extension)
1 OUT=IN1+IN2
2 OUT = IN1 - IN2
3 OUT=IN1*IN2
4 OUT = IN1 / IN2
5 OUT = IN1 / (100 - IN2)
C0601
Selection list 1 Configuration of analog input
signal, function block ARIT2
1 CFG: IN 1000 FIXED0% ARIT2-IN1
2 CFG: IN 1000 FIXED0% ARIT2-IN2
C0602 -199.99 {0.01 %} 199.99 Function block ARIT2
z Display of the signals linked in
C0601
1 DIS: IN ARIT2-IN1
2 DIS: IN ARIT2-IN2