EasyManuals Logo
Home>Lenze>DC Drives>EVF9327

Lenze EVF9327 User Manual

Lenze EVF9327
459 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #330 background imageLoading...
Page #330 background image
Configuration
Code table
8
8.3
8.3-21
EDSVF9333V EN 3.0-06/2005
IMPORTANTPossible settingsCode
SelectionLenzeNameNo.
C0260 MPOT1 high 100.00 -199.99 {0.01 %} 199.99 Upper limit, function block
MPOT1
z Condition: C0260 > C0261
See System
Manual
(extension)
C0261 MPOT1 low -100.0 -199.99 {0.01 %} 199.99 Lower limit, function block
MPOT1
z Condition: C0261 < C0260
C0262 MPOT1 TIR 10.0 0.1 {0.1 s} 6000.0 Acceleration time T
ir
, function
block MPOT1
z The set time refers to a change
of 0 ... 100 %
C0263 MPOT1 Tif 10.0 0.1 {0.1 s} 6000.0 Deceleration time T
if
, function
block MPOT1
Motor potentiometer
z The set time refers to a change
of 100 ... 0 %
C0264 MPOT1 on/off 0
0 no change
Deactivation of motor
potentiometer, function block
MPOT1
z Function is executed when
MPOT1-INACT = HIGH
1 Deceleration with T
if
to 0%
2 Deceleration with T
if
to C0261
3 Jump with T
if
=0to0%
4 Jump with T
if
= 0 to C0261
5 Acceleration with T
ir
to C0260
C0265 MPOT1 INIT 0
0 Value of MPOT1 when mains fails
Initialisation of motor
potentiometer, function block
MPOT1
z Starting value which is to be
accepted during mains
switching and activated motor
potentiometer
1 lower limit of C0261
2 0%
C0267
Selection list 2 Configuration of digital input
signals, function block MPOT
See System
Manual
(extension)
1 CFG: UP 1000 FIXED0
UP DOWN MPOT1-OUT
00
01
10
11
: Output signal runs to the upper limit
value
: Output signal runs to the lower limit
value
: Output signal is unchanged
2 CFG: DOWN 1000 FIXED0
C0268
CFG: INACT 1000 FIXED0 Selection list 2 Configuration of digital input
signal, function block MPOT
z HIGH: motor potentiometer is
not active. Output signal runs
to 0
C0269
Digital input signals, function
block MPOT
z Display of the signals linked in
C0267 and C0268
1 DIS: UP
2 DIS: DOWN
3 DIS: INACT

Table of Contents