[2021-05-14 14:40:50.179] [ INFO] [ 192.168.1.14] - [tps_family_ps171.bin]'s version in the package: 1.0.6b0
r522
[2021-05-14 14:41:06.386] [ INFO] [ 192.168.1.14] - [tps_family_ps171.bin]'s firmware version updated in FVS
EEPROM.
[2021-05-14 14:41:12.514] [ INFO] [ 192.168.1.14] - Setting system information...
[2021-05-14 14:41:18.637] [ INFO] [ 192.168.1.14] - Starting application...
[2021-05-14 14:43:03.605] [ INFO] [ 192.168.1.14] - Waiting for VS100...
[2021-05-14 14:43:05.237] [ INFO] [ 192.168.1.14] - Restoring device settings from the following backup file:
c:\My_backup\backup_91540050_00006363_2021-05-14_14-39-28_converted.lw3 ...
[2021-05-14 14:43:14.325] [ INFO] [ 192.168.1.14] - Device settings have been restored
[2021-05-14 14:43:14.358] [ INFO] [ 192.168.1.14] - Resetting device...
[2021-05-14 14:43:19.071] [ INFO] [ 192.168.1.14] - Done
All 1 update(s) finished successfully.
Example 3
The following options applied:
Cleartext login password is applied
Custom backup folder is set

Firmware is not updated but the process and the connection is tested
C:\Program Files (x86)\Lightware\Lightware Device Updater V2>LightwareDeviceUpdaterV2_CLI.cmd update --test --ip
192.168.1.14 --package c:\Firmwares\umx-tps-tx100_v1.5.0b4.lfp2 --backupFolder c:\My_backup --clearTextLoginPw
qwer1234
C:\Program Files (x86)\Lightware\Lightware Device Updater V2>lib\jre\bin\java.exe -jar lib\ldu2.jar update --test
--ip 192.168.1.14 --package c:\Firmwares\umx-tps-tx100_v1.5.0b4.lfp2 --backupFolder c:\My_backup --clearTextLoginPw
qwer1234
[2021-05-14 14:45:37.351] [ INFO] [ main] - Device IPs: [192.168.1.14]
[2021-05-14 14:45:40.396] [ WARN] [ pool-2-thread-1] - NetworkMask property is not available. Cannot determine
whether the device is on the same network or not.
[2021-05-14 14:45:40.481] [ WARN] [ pool-2-thread-1] - Bonjour device builder error messages: [object Array]
[2021-05-14 14:45:40.551] [ INFO] [ main] - All the selected devices are accessible over the network.
[2021-05-14 14:45:40.748] [ INFO] [ main] - All the selected devices are compatible with the specified
package.
[2021-05-14 14:45:41.347] [ INFO] [ 192.168.1.14] - PASSED - Test #01 - Communication over LW3
[2021-05-14 14:45:41.427] [ INFO] [ 192.168.1.14] - PASSED - Test #02 - Cleartext login - PW is correct
[2021-05-14 14:45:41.474] [ INFO] [ 192.168.1.14] - Creating backup of device settings...
[2021-05-14 14:45:45.010] [ INFO] [ 192.168.1.14] - Backup HTTP enable properties
[2021-05-14 14:45:47.417] [ INFO] [ 192.168.1.14] - HTTP and HTTP post have got enabled on port 80
[2021-05-14 14:45:47.620] [ INFO] [ 192.168.1.14] - No miniweb file is found on the device.
[2021-05-14 14:45:50.058] [ INFO] [ 192.168.1.14] - HTTP and HTTP post properties have got restored on port 80
[2021-05-14 14:45:50.060] [ INFO] [ 192.168.1.14] - PASSED - Test #03 - Configuration and/or device preset
backup created
[2021-05-14 14:45:50.080] [ INFO] [ 192.168.1.14] - Switching device into bootload mode...
[2021-05-14 14:45:51.721] [ INFO] [ 192.168.1.14] - PASSED - Test #04 - Switch device into bootloader mode
[2021-05-14 14:46:09.050] [ INFO] [ 192.168.1.14] - PASSED - Test #05 - Communication with bootloader
[2021-05-14 14:46:09.063] [ INFO] [ 192.168.1.14] - Gathering UID information from device...
[2021-05-14 14:46:09.403] [ INFO] [ 192.168.1.14] - PASSED - Test #06 - TFTP file transfer
[2021-05-14 14:46:22.638] [ INFO] [ 192.168.1.14] - PASSED - Test #07 - Start application FW
[2021-05-14 14:46:22.681] [ INFO] [ 192.168.1.14] - Done
All 1 update(s) finished successfully.
Exit Codes

Code Displayed text Description
0  The update performed successfully
1 Update error (ErrorCode:1) The error happened during the update
2  The error happened before starting the update
The error line contains further information about the error.

®
c:\Program Files (x86)\Lightware\Lightware Device Updater V2\echo %errorlevel%
0

echo $?
0
So if this value is queried after the update and it is 0, the update performed successfully.
If the Update is not successful
Restart the process and try the update again.

written in the User's manual of the device. Please note that backup and restore cannot be performed
in this case.
If the backup cannot be created for some reason, you will get a message to continue the process
without backup or stop the update. A root cause can be that the desired device is already in bootload

If an update is not successful, the Export log button becomes red. If you press the button, you can

 #bootload

Table of Contents

Other manuals for Lightware UMX-TPS-TX100 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lightware UMX-TPS-TX100 Series and is the answer not in the manual?

Lightware UMX-TPS-TX100 Series Specifications

General IconGeneral
BrandLightware
ModelUMX-TPS-TX100 Series
CategoryTransmitter
LanguageEnglish

Related product manuals