8. Firmware Update UMX-TPS-TX100 series – User's Manual 157
[2021-05-14 14:40:50.179] [ INFO] [ 192.168.1.14] - [tps_family_ps171.bin]'s version in the package: 1.0.6b0
r522
[2021-05-14 14:41:06.386] [ INFO] [ 192.168.1.14] - [tps_family_ps171.bin]'s firmware version updated in FVS
EEPROM.
[2021-05-14 14:41:12.514] [ INFO] [ 192.168.1.14] - Setting system information...
[2021-05-14 14:41:18.637] [ INFO] [ 192.168.1.14] - Starting application...
[2021-05-14 14:43:03.605] [ INFO] [ 192.168.1.14] - Waiting for VS100...
[2021-05-14 14:43:05.237] [ INFO] [ 192.168.1.14] - Restoring device settings from the following backup file:
c:\My_backup\backup_91540050_00006363_2021-05-14_14-39-28_converted.lw3 ...
[2021-05-14 14:43:14.325] [ INFO] [ 192.168.1.14] - Device settings have been restored
[2021-05-14 14:43:14.358] [ INFO] [ 192.168.1.14] - Resetting device...
[2021-05-14 14:43:19.071] [ INFO] [ 192.168.1.14] - Done
All 1 update(s) finished successfully.
Example 3
The following options applied:
▪ Cleartext login password is applied
▪ Custom backup folder is set
▪
▪ Firmware is not updated but the process and the connection is tested
C:\Program Files (x86)\Lightware\Lightware Device Updater V2>LightwareDeviceUpdaterV2_CLI.cmd update --test --ip
192.168.1.14 --package c:\Firmwares\umx-tps-tx100_v1.5.0b4.lfp2 --backupFolder c:\My_backup --clearTextLoginPw
qwer1234
C:\Program Files (x86)\Lightware\Lightware Device Updater V2>lib\jre\bin\java.exe -jar lib\ldu2.jar update --test
--ip 192.168.1.14 --package c:\Firmwares\umx-tps-tx100_v1.5.0b4.lfp2 --backupFolder c:\My_backup --clearTextLoginPw
qwer1234
[2021-05-14 14:45:37.351] [ INFO] [ main] - Device IPs: [192.168.1.14]
[2021-05-14 14:45:40.396] [ WARN] [ pool-2-thread-1] - NetworkMask property is not available. Cannot determine
whether the device is on the same network or not.
[2021-05-14 14:45:40.481] [ WARN] [ pool-2-thread-1] - Bonjour device builder error messages: [object Array]
[2021-05-14 14:45:40.551] [ INFO] [ main] - All the selected devices are accessible over the network.
[2021-05-14 14:45:40.748] [ INFO] [ main] - All the selected devices are compatible with the specified
package.
[2021-05-14 14:45:41.347] [ INFO] [ 192.168.1.14] - PASSED - Test #01 - Communication over LW3
[2021-05-14 14:45:41.427] [ INFO] [ 192.168.1.14] - PASSED - Test #02 - Cleartext login - PW is correct
[2021-05-14 14:45:41.474] [ INFO] [ 192.168.1.14] - Creating backup of device settings...
[2021-05-14 14:45:45.010] [ INFO] [ 192.168.1.14] - Backup HTTP enable properties
[2021-05-14 14:45:47.417] [ INFO] [ 192.168.1.14] - HTTP and HTTP post have got enabled on port 80
[2021-05-14 14:45:47.620] [ INFO] [ 192.168.1.14] - No miniweb file is found on the device.
[2021-05-14 14:45:50.058] [ INFO] [ 192.168.1.14] - HTTP and HTTP post properties have got restored on port 80
[2021-05-14 14:45:50.060] [ INFO] [ 192.168.1.14] - PASSED - Test #03 - Configuration and/or device preset
backup created
[2021-05-14 14:45:50.080] [ INFO] [ 192.168.1.14] - Switching device into bootload mode...
[2021-05-14 14:45:51.721] [ INFO] [ 192.168.1.14] - PASSED - Test #04 - Switch device into bootloader mode
[2021-05-14 14:46:09.050] [ INFO] [ 192.168.1.14] - PASSED - Test #05 - Communication with bootloader
[2021-05-14 14:46:09.063] [ INFO] [ 192.168.1.14] - Gathering UID information from device...
[2021-05-14 14:46:09.403] [ INFO] [ 192.168.1.14] - PASSED - Test #06 - TFTP file transfer
[2021-05-14 14:46:22.638] [ INFO] [ 192.168.1.14] - PASSED - Test #07 - Start application FW
[2021-05-14 14:46:22.681] [ INFO] [ 192.168.1.14] - Done
All 1 update(s) finished successfully.
Exit Codes
Code Displayed text Description
0 The update performed successfully
1 Update error (ErrorCode:1) The error happened during the update
2 The error happened before starting the update
The error line contains further information about the error.
®
c:\Program Files (x86)\Lightware\Lightware Device Updater V2\echo %errorlevel%
0
echo $?
0
So if this value is queried after the update and it is 0, the update performed successfully.
If the Update is not successful
▪ Restart the process and try the update again.
▪
written in the User's manual of the device. Please note that backup and restore cannot be performed
in this case.
▪ If the backup cannot be created for some reason, you will get a message to continue the process
without backup or stop the update. A root cause can be that the desired device is already in bootload
▪ If an update is not successful, the Export log button becomes red. If you press the button, you can
#bootload