UMX-TPS-TX100 series – User's Manual 94
Enable/disable the Ethernet Port
Command and Response
ȩ <switch>}
Ȩ <switch>
Parameters
If the <switch> parameter is 0, the port is disabled. If its value is 1, the port is enabled.
Example
ȩ
Ȩ
RS-232 Settings
RS-232 Mode Setting
RS -232 mode can be set as follows. See more details about RS -232 modes in the Serial Interface section.
#rs232 #rs-232 #serial #commandinjection
Command and Response
ȩ {RS232=<mode>}
Ȩ (RS232=<mode>
Parameters
Parameter Parameter description Value Parameter value
<mode> RS-232 operation mode
CONTROL Control mode
CI Command injection mode
PASS Event Manager (Pass-through) mode
Example
ȩ {rs232=control}
Ȩ
INFO:
RS-232 Parameters Settings
The parameters of local RS -232 port can be set as follows.
Command and Response
ȩ <BaudRate>;<DataBit>;<Parity>;<StopBit>}
Ȩ <BaudRate>;<DataBit>;<Parity>;<StopBit>
Parameters
Parameter Parameter description Value Parameter value
<BaudRate> Baud rate
X No change
4800 4800
7200 7200
9600
14400 14400
19200 19200
38400 38400
57600
115200 115200
<DataBit> Data bit
X No change
8 8
9 9
<Parity> Parity
X No change
N None
E Even
O Odd
<StopBit> Stop Bit
X No change
1 1
1,5 1,5
2 2
Example
ȩ
Ȩ
Explanation
changed, remained 1.
INFO: